New Products

NDS ScaleOR, SDI Input, w/ fiber 90T0012
NDS ScaleOR, SDI Input, w/ fiber 90T0012
Please login for prices
excl. 19 % Tax

Welcome back !

TNetz. MPU100-107 2.5x5.5x9.5mm W

TNetz. MPU100-107 2.5x5.5x9.5mm W
TNetz. MPU100-107 2.5x5.5x9.5mm W
Product No.: 2005933
Please login for prices

Shipping time: 3-4 Days
Print product data sheet 

Produktbeschreibung

Safety: DIN EN 60601-1 (Medical electrical equipment)

EMC: DIN EN 60601-1-2 (Medical electrical equipment)


The MPU100 series of AC/DC switching mode power supplies provide 100 Watts of continuous output power . All supplies are UL94V-1 min compliant, include IEC-320-C14 input for worldwide applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed  to comply with UL/c-UL(UL 60601-1) ,TUV/T-mark (EN 60601-1) and new CE requirements. All units are 100% burned in and tested. They are suited for use in hospital instrument and many other applications.

Features:

  -  Wide Input Voltage 90 to 264 VAC,47 to 63 Hz

  -  IEC-320-C14 Input Inlet

  -  Output plug: 2.5mm (inside) x 5.5mm (outside) x 9.5mm (length) barrel plug, angled

  -  Output Voltage 19VDC

  -  Input Surge Current, Over Voltage And Over Load protection

  -  Output Voltage Protection

  -  Ultra-low leakage current (under 0.1mA)

  -  Power Factor Correction

  -  Class I Insulation

  -  ON/OFF SWITCH

Electrical Characteristics:

  -  Efficiency: 88% max

  -  Adj. Output Voltage 16 - 21 VDC

  -  Max. Output Current: 6.3 - 4.8 A

  -  Total Regulation: 5%

  -  Max. Output Power: 100W

  -  Line Regulation: 1% max.

  -  Load Regulation: 5% max.

  -  Hold-up Time: 16mS Typ.

  -  Output ripple and noise: 1% (Typ.)

Environmental:

  -  Operating Temperature: 0 to 70°C

  -  Storage Temperature: -40 to 85°C

  -  Relative Humidity: 5 to 95%

Sym Parameter Test  Conditions Min Typ Max Unit
Vps Dielectric Withstanding Voltage for Primary  to secondary Primary to secondary 5656     VDC
Vpg

Dielectric Withstanding Voltage for Primary  to secondary

Primary to ground 2800     VDC
Ris Isolation  Resistance   Io=Full load,Vin=230VAC    50    

MΩ

CISPR

EMI  requirements for CISPR-11   

Vin=220VAC          

B     CLASS
FCC EMI  requirements for  FCC PART-18

Vin=110VAC

B     CLASS

 

 

 

 

Weitere Produktfotos

  • TNetz. MPU100-107 2.5x5.5x9.5mm W

We recommend following products:

Gerätezuleitung MED Winkel Schuko C13 1.8m

Gerätezuleitung MED Winkel Schuko C13 1.8m
Please login for prices
excl. 19 % Tax


nach oben
Parse Time: 0.664s